- Isotope Products
- Isotrak Calibration Sources
- Isotrak News
- PT and Cross Check Programs
- Isotrak Product Finder
- Reference Sources
- Standardized Solutions
- Education and Training
- Gas Standards
- Instruments
- Calibration Services
- Downloads
- General Technical Information
- Distributors
- Certifications
- Medical Imaging Sources & SPECT Diagnostics
- General Business Terms
- Industrial Sources
- Bulk Isotopes / Scientific Resources
- Umweltdienste
- Radioactivity Unit Converter
- Decay Chart Generator
- Isotrak Calibration Sources
X-ray Sources
The products shown on these pages are representative sources used for common applications.
If you cannot find the product with your specifications, please contact us using the corresponding email contact on this website. In most cases we will be able provide you with a solution meeting your requirements.
You can also use our product request forms.
Download catalogue.
X-ray and low energy photon sources (6 keV – 80 keV)
Application
These sources have been designed to minimize self-absorption of low energy photons, so they are suitable for calibrating X-ray spectrometers such as Si(Li) detectors. For energy calibration only, a more robust source design is used.
Construction
A thin deposit of active material 5mm in diameter is heat sealed between plastic foils. The foils are mounted in an aluminium frame 25mm in diameter, 3mm thick (drawing VZ-1562-001). The 20 -37 kBq sources are sealed between foils 0.1mm and 0.015mm thick, with the thinner foil on the engraved side.
Ordering Information VZ-1562-001
Radionuclide | Activity [kBq] | Product code | Calibration |
---|---|---|---|
Am-2411) | 37 | AMRB21522 | activity calibrated |
Ba-133 | 37 | BDRB21523 | activity calibrated |
Cd-109 | 37 | CURB21524 | activity calibrated |
Co-57 | 37 | CTRB21525 | activity calibrated |
Fe-55 | 37 | IERB21469 | not calibrated only |
Nb-93m | 20 | NHRB22161 | not calibrated only |
Pb-210 | 37 | RBRB21526 | activity calibrated |
Zn-65 | 37 | ZARB21527 | activity calibrated |
1) Source should be wipe-tested regularly.
Ordering information VZ-4080-001
Radionuclide | Activity [kBq] (Activity calibrated) |
Product code |
---|---|---|
Fe-55 | 370 | IERB23027 |
Ordering information VZ-4081-001
Radionuclide | Activity [kBq] (Activity calibrated) |
Product code |
---|---|---|
Am-2411) | 37 | AMRB23057 |
Ba-133 | 370 | BDRB23055 |
Cd-109 | 370 | CURB23058 |
Co-57 | 370 | CTRB23056 |
1) Source should be wipe-tested regularly.
Robust source for energy calibration
Construction
The radioactive isotope is absorbed in an ion-exchange bead approximately 1mm in diameter. The bead is fixed inside a solid plastic capsule. The active bead is visible, and located at the geometric centre of the source. This source is uncalibrated and is intended for energy calibration only.
ISO classification
ISO/12/C34343
Drawing: VZ-1240-001
Ordering Information
Radionuclide | Nominal activity [MBq] (not calibrated) |
Product code |
---|---|---|
Fe-55 | 1.85 | IER15510 |