{"id":187,"date":"2023-07-31T14:55:04","date_gmt":"2023-07-31T14:55:04","guid":{"rendered":"https:\/\/www.ezag.com\/?page_id=187"},"modified":"2024-10-02T10:10:27","modified_gmt":"2024-10-02T10:10:27","slug":"beta-secondary-standard-2-bss-2","status":"publish","type":"page","link":"https:\/\/www.ezag.com\/de\/produkte\/isotope-products\/isotrak-calibration-sources\/instruments\/beta-secondary-standard-2-bss-2\/","title":{"rendered":"Beta Secondary Standard"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":185,"menu_order":178,"comment_status":"closed","ping_status":"closed","template":"produkte-template.php","meta":{"_acf_changed":false},"class_list":["post-187","page","type-page","status-publish","hentry"],"acf":{"header":[{"acf_fc_layout":"modul_hero","select":"no","breadcrumb":false,"bild":"","headline":"","headlinetype":"p","headlineclass":"p","subline":"","sublinetype":false,"sublineclass":false,"text":"","links":[{"link":""}],"id":"","abstand_oben":true,"abstand_unten":true}],"module":[{"acf_fc_layout":"modul_linkliste","headline":"Beta Secondary Standard 2 (BSS-2)","headlinetype":"h1","headlineclass":"h2","text":"","links":[{"link":{"title":"go directly to the New Upgraded BSS2","url":"#c3258","target":""}},{"link":{"title":"go directly to the BSS2 Upgrade packages","url":"#c3259","target":""}}],"id":"","abstand_oben":true,"abstand_unten":true},{"acf_fc_layout":"modul_text","headline":"Application \/ Description","headlinetype":"h3","headlineclass":"bodytitle","text":"The Beta Secondary Standard (BSS) was first developed by the German National Metrology Institute Physikalisch-Technische Bundesanstalt (PTB) nearly 30 years ago for calibrating personal dosimeters and survey instruments for beta radiation. Calibrations are traceable to the PTB\u2019s primary standard, and the BSS meets the requirements of ISO6980.","link":"","link2":"","file":"","btnausrichtung":"align-left","id":"","textrahmen":false,"twocoloum":false,"tableshort":false,"abstand_oben":false,"abstand_unten":true},{"acf_fc_layout":"modul_bildtext","bild":7112,"select":"br","bbreite":"50_50","textbildausrichtung":"txtcenter","headline":"","headlinetype":"p","headlineclass":"p","text":"&nbsp;\r\n\r\nThe new BSS (BSS-2), also developed by PTB, is a complete irradiation facility including beta sources, mechanics, electronics, sensors for air pressure, temperature and humidity, and a personal computer to control all irradiation parameters and to deliver the desired dose to the instrument under test.\r\n\r\n&nbsp;","link":"","file":"","file2":"","id":"","abstand_oben":true,"abstand_unten":true},{"acf_fc_layout":"modul_text","headline":"","headlinetype":"p","headlineclass":"p","text":"<strong>The main features of the new facility are:<\/strong>\r\n<ul>\r\n \t<li>Dosimeters can be positioned easily at the calibrated point in the radiation field<\/li>\r\n \t<li>Irradiation table rotates in 5 degree steps for measuring polar response<\/li>\r\n \t<li>High activity Pm-147, Kr-85 and Sr-90 sources with beam flattening filters in place<\/li>\r\n \t<li>Sr-90 source also calibrated without filter for source-detector distances of 11, 30 and 50cm<\/li>\r\n \t<li>Each source contained in an individual shield with built-in shutter -reduced operator dose, no special handling equipment needed<\/li>\r\n \t<li>Low activity Tl-204 source replaced by high activity Kr-85 source<\/li>\r\n<\/ul>\r\n&nbsp;\r\n\r\nFor quality assurance purposes and to deliver the required dose to the dosimeter, the computer automatically records the following parameters:\r\n<ol>\r\n \t<li>Radionuclide and source identification number<\/li>\r\n \t<li>Type of beam flattening filter<\/li>\r\n \t<li>Distance between source and dosimeter<\/li>\r\n \t<li>Angle of incidence of radiation<\/li>\r\n \t<li>Temperature, humidity and air pressure<\/li>\r\n<\/ol>\r\n&nbsp;\r\n<h3 id=\"c3258\">Upgraded version of the complete Beta Secondary Standard BSS2 <strong>(Since: 2017-02-01)<\/strong><\/h3>\r\n<strong>Complete Beta irradiation facility BSS-2 comprising:<\/strong>\r\n<table class=\"border_and_background\">\r\n<tbody>\r\n<tr>\r\n<th>Product Code<\/th>\r\n<th>Qty<\/th>\r\n<th>Description<\/th>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB6243<\/td>\r\n<td>1<\/td>\r\n<td>Beta Secondary Standard 2\r\nBasic irradiation facility including mechanics<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB7583<\/td>\r\n<td>1<\/td>\r\n<td>Sensor for temperature and humidity<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB21463<\/td>\r\n<td>1<\/td>\r\n<td>Beta Secondary Standard 2 (BSS-2)\r\nElectronic control unit including- Integrated PC and data storage\r\n- Monitor und keyboard with touchpad - PTB software, correction factors and Calibration data of the sources - Data interface<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB7579<\/td>\r\n<td>1<\/td>\r\n<td>Digital Barometer\r\n(Mounted into the electronic control unit)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB15800<\/td>\r\n<td>1<\/td>\r\n<td>Rod phantom - Including storage case<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB21349<\/td>\r\n<td>1<\/td>\r\n<td>Slab phantom - Including storage case<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB7581<\/td>\r\n<td>1<\/td>\r\n<td>Suitcase including accessories and tools<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>QCRB6245<\/td>\r\n<td>1<\/td>\r\n<td>Set of 3 beta radiation sources for BSS-2\r\nconsisting of:\r\n- Pm-147 source (PHRB4809) 3,7 GBq according to drawing VZ-1407-001\r\n- Kr-85 source (KARB4810) 3,7 GBq according to drawing VZ-2832-002\r\n- Sr-90 source (SIRB4568) 460 MBq according to drawing VZ-2104-001\r\nEach source is calibrated by the German National Metrology Institute\u201dPhysikalisch-Technische Bundesanstalt\u201d (PTB) and is mounted in a stainless steel holder incl. lead pot with beam flattening filter. The sources will be supplied in Type A approved packaging.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n&nbsp;\r\n\r\nOne wooden Box containing the mechanic and electronic systems.\r\nOne Type A packaging containing the radiation source set.\r\n\r\n<strong>Option:<\/strong>\r\nOn site Installation of the system and training only as far as the operation of the unit is concerned. No training on beta dosimetry incl. travel and accommodation\r\n\r\nThe system consists of 2 boxes:\r\n1) the radioactive sources - Type A package - UN2915\r\ndim.: 0.78m x 0.34m x 0.55m, weight 25kg\r\n7.9GBq (Sr-90,Kr-85,Pm-147)\r\nestimated labelling: II Yellow, max. Ti: 0.2 or below\r\n2) all inactive parts of the equipment are packed into a wooden box\r\ndim: 1.19m x 0.7m x 1.26m, weight 60kg","link":"","link2":"","file":764,"btnausrichtung":"align-left","id":"","textrahmen":false,"twocoloum":false,"tableshort":false,"abstand_oben":true,"abstand_unten":true},{"acf_fc_layout":"modul_text","headline":"","headlinetype":"p","headlineclass":"p","text":"<h3 id=\"c3259\">Upgrade packages for the former complete Beta Secondary Standard BSS-2 versions (delivered not earlier than 10 years)<\/h3>\r\n<table class=\"border_and_background\">\r\n<tbody>\r\n<tr>\r\n<th>Upgrade Package 1<\/th>\r\n<\/tr>\r\n<tr>\r\n<th>Product Code<\/th>\r\n<th>Qty<\/th>\r\n<th>Description<\/th>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB21463<\/td>\r\n<td>1<\/td>\r\n<td>Beta Secondary Standard 2 (BSS-2)\r\nElectronic control unit including\r\n- Integrated PC and data storage\r\n- Monitor und keyboard with touchpad - PTB software, correction factors and Calibration data of the sources - Data interface<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB7579<\/td>\r\n<td>1<\/td>\r\n<td>Digital Barometer\r\n(Mounted into the electronic control unit)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB15800<\/td>\r\n<td>1<\/td>\r\n<td>Rod phantom - Including storage case<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB21349<\/td>\r\n<td>1<\/td>\r\n<td>Slab phantom - Including storage case<\/td>\r\n<\/tr>\r\n<tr>\r\n<th>Upgrade Package 2<\/th>\r\n<\/tr>\r\n<tr>\r\n<th>Product Code<\/th>\r\n<th>Qty<\/th>\r\n<th>Description<\/th>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB21463<\/td>\r\n<td>1<\/td>\r\n<td>Beta Secondary Standard 2 (BSS-2)\r\nElectronic control unit including\r\n- Integrated PC and data storage\r\n- Monitor und keyboard with touchpad - PTB software, correction factors and Calibration data of the sources - Data interface<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB7579<\/td>\r\n<td>1<\/td>\r\n<td>Digital Barometer\r\n(Mounted into the electronic control unit)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB15800<\/td>\r\n<td>1<\/td>\r\n<td>Rod phantom - Including storage case<\/td>\r\n<\/tr>\r\n<tr>\r\n<th>Upgrade Package 3<\/th>\r\n<\/tr>\r\n<tr>\r\n<th>Product Code<\/th>\r\n<th>Qty<\/th>\r\n<th>Description<\/th>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB21463<\/td>\r\n<td>1<\/td>\r\n<td>Beta Secondary Standard 2 (BSS-2)\r\nElectronic control unit including\r\n- Integrated PC and data storage\r\n- Monitor und keyboard with touchpad - PTB software, correction factors and Calibration data of the sources - Data interface<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB7579<\/td>\r\n<td>1<\/td>\r\n<td>Digital Barometer\r\n(Mounted into the electronic control unit)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB21349<\/td>\r\n<td>1<\/td>\r\n<td>Slab phantom - Including storage case<\/td>\r\n<\/tr>\r\n<tr>\r\n<th>Upgrade Package 4<\/th>\r\n<\/tr>\r\n<tr>\r\n<th>Product Code<\/th>\r\n<th>Qty<\/th>\r\n<th>Description<\/th>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB21463<\/td>\r\n<td>1<\/td>\r\n<td>Beta Secondary Standard 2 (BSS-2)\r\nElectronic control unit including\r\n- Integrated PC and data storage\r\n- Monitor und keyboard with touchpad - PTB software, correction factors and Calibration data of the sources - Data interface<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>NIGB7579<\/td>\r\n<td>1<\/td>\r\n<td>Digital Barometer\r\n(Mounted into the electronic control unit)<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n&nbsp;","link":{"title":"Back to New Products","url":"https:\/\/www.ezag.com\/de\/produkte\/isotope-products\/isotrak-calibration-sources\/isotrak-news\/new-products\/","target":""},"link2":{"title":"Back to Top - BSS2","url":"https:\/\/www.ezag.com\/de\/produkte\/isotope-products\/isotrak-calibration-sources\/instruments\/beta-secondary-standard-2-bss-2\/","target":""},"file":"","btnausrichtung":"align-left","id":"","textrahmen":false,"twocoloum":false,"tableshort":false,"abstand_oben":false,"abstand_unten":false}],"thumb":"","kurzbeschreibung":""},"_links":{"self":[{"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/pages\/187","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/comments?post=187"}],"version-history":[{"count":38,"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/pages\/187\/revisions"}],"predecessor-version":[{"id":8614,"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/pages\/187\/revisions\/8614"}],"up":[{"embeddable":true,"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/pages\/185"}],"wp:attachment":[{"href":"https:\/\/www.ezag.com\/de\/wp-json\/wp\/v2\/media?parent=187"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}